Spirometer Training Unit
Spirometer (spy-ROM-uh-tree) is a common office test used to assess how well your lungs work by measuring how much air you inhale, how much you exhale and how quickly you exhale. Spirometer is used to diagnose asthma, chronic obstructive pulmonary disease (COPD) and other conditions that affect breathing. Spirometry may also be used periodically to check whether a treatment for a chronic lung condition is helping you breathe better The trainer is designed to demonstrate the operation, theory, repair and servicing of Spirometer equipment that used at clinics & hospitals. The unit is given the fault diagnosis so as to facilitate the teaching of trouble shooting techniques. A fault simulator is provided with circuit block diagram of the device for the students to study theoretically and experimentally in order to understand the operation of the device.
Model Number: MIT-SPM-1B
Ventilator Training Unit
A medical ventilator is a mechanical ventilator, a machine designed to move breathable air into and out of the lungs, to provide breathing for a patient who is physically unable to breathe, or breathing insufficiently. While modern ventilators are computerized machines, patients can be ventilated with a simple, handoperated bag valve mask. Ventilators are chiefly used in intensive care medicine, home care, and emergency medicine (as standalone units) and in anesthesia (as a component of an anesthesia machine). This trainer is designed to demonstrate the operation, theory, repair and servicing of Electrical Ventilator equipment that used at clinics & hospitals. The unit is given the fault diagnosis so as to facilitate the teaching of trouble shooting techniques. A fault simulator is provided with circuit block diagram of the device for the students to study theoretically and experimentally in order to understand the operation of the device.
Model Number: MIT-EVL-1
Infusion Injection Pump Trainer
An Infusion Injection Pump is a medical device used to deliver fluids into a patient’s body in a controlled manner. Labtech Infusion Injection pump is designed to demonstrate the operation, theory, repair and servicing of Infusion Injection pump equipment that used at clinics & hospitals. The unit is given the fault diagnosis so as to facilitate the teaching of trouble shooting techniques. A fault simulator is provided with circuit block diagram of the device for the students to study theoretically and experimentally in order to understand the operation of the device.
Model Number: MIT-IPT-1
Nebulizer Trainer
Nebulizers are commonly used for the treatment of asthma, cystic fibrosis, COPD and other respiratory diseases or disorders. Labtech Nebulizer Trainer is designed to demonstrate the operation, theory, repair and servicing of Nebulizer equipment that used at clinics & hospitals. The unit is given the fault diagnosis so as to facilitate the teaching of trouble shooting techniques. A fault simulator is provided with circuit block diagram of the device for the students to study theoretically and experimentally in order to understand the operation of the device.
Model Number: MIT-NBZ-1
Heart Lung Machine Trainer
Heart-lung machine (HLM), also called oxygenator pump or cardiopulmonary bypass (CPB) pump, aims to provide extracorporeal circulation (ECC) with maintenance of oxygenated blood flow to the body organs when the device is connected to the arteriovenous system. The HLM is an essential component of open-heart surgery to bypass the circulatory system of the heart and lungs, termed CPB. The main principle is to draw the blood from the major veins (venae cavae) to an oxygenator in the HLM where it is re-oxygenated, and then pumped into the arterial system (ascending aorta). Additionally, the myocardial contractility during CPB can be halted by running a cardioplegic solution containing potassium citrate. The trainer is designed to demonstrate the operation, theory, repair and servicing of heart lung machine equipment that used at clinics & hospitals. The unit given the fault diagnosis so as to facilitate the teaching of trouble shooting techniques. A fault simulator is provided with circuit block diagram of the device for the students to study theoretically and experimentally in order to understand the operation of the device.
Model Number: MIT-HLM-1